An emergency order issued by the United States Department of Energy (DOE) under Section 202(c) of the Federal Power Act. It allows the Secretary of Energy to temporarily order connections of facilities and the generation, delivery, or transmission of electricity to best meet an emergency caused by war, a sudden increase in demand, or a shortage of energy or facilities. These temporary orders can also exempt power plants from federal, state, or local environmental rules and have historically been used to prevent outages during severe weather events or supply shortfalls.
An independent agency that regulates the interstate transmission of natural gas, oil, and electricity. FERC also regulates natural gas and hydropower projects.
A United States law primarily regulating the interstate transmission and sale of electricity and the development of hydroelectric power. It was responsible for creating the body now known as FERC. It was created in 1920 and has been amended several times since.
Measures taken to ensure backup power, particularly of renewable energy, such as solar and wind generators. These requirements may require battery storage, ancillary services, or backup generation, such as an added gas plant to produce energy when a solar or wind plant does not.
Electricity is supplied to homes and businesses in the United States in the form of alternating current, and frequency is the rate at which an alternating current changes direction, as measured in hertz (Hz). Across the power grid there is a consistent frequency which in the United States is 60 Hz.
The ability of the grid to react to a change in
the frequency to bring it back to the normal operating frequency, which is 60 Hz in the United States
The process of creating electricity.
Heat derived from the Earth’s interior, which can be harnessed for electricity generation. It’s a renewable resource, as the Earth’s internal heat is continuously replenished.
The electrical grid is a vast, interconnected network comprising power plants, transmission lines, substations, and distribution lines. Its purpose is to generate, transmit, and deliver electricity from producers to consumers across a wide geographic area.
A variety of technologies that improve the capacity, efficiency, and reliability of existing power grids. They are often lower cost and faster to deploy than major grid infrastructure upgrades like building new transmission lines. These technologies optimize the flow of electricity across existing infrastructure.
Refers to the ability of an inverter to synchronize with frequency and voltage on the grid. These are more common than grid forming and refer to how this technology takes its cues from the grid, not the other way around.
Refers to the ability of an inverter to actively control frequency and voltage on the grid, helping to ensure grid stability. They can provide ancillary services, such as inertia, voltage regulation, and frequency response, essential for maintaining grid stability.
Refers to the many solutions that help the grid withstand major events, such as extreme weather, natural disasters, or cyber attacks, without disruption.
Fuel cell that carries energy generated from another source. It can be used in fuel cells to generate electricity with water as the only byproduct, or it can be burned for heat. Hydrogen can be produced from a variety of sources–renewable energy such as solar or wind, or gas plants, nuclear, and other energy sources–which dictate whether it can be considered “clean” or not.
An entity that is hired by an Independent System Operator (ISO) or Regional Transmission Organization (RTO) to oversee and assess the operations of the wholesale electricity market. Its primary role is to ensure fair and competitive market practices by monitoring market participant behavior and identifying potential market manipulation or design flaws.
A non-profit organization that manages the electricity grid and wholesale electricity markets within a specific geographic region. Its primary role is to ensure the reliable and efficient delivery of electricity, balancing supply and demand in real-time and overseeing fair competition among market participants.
In the context of the grid, it refers to the energy stored in the rotating machinery of generators, such as the turbines of a gas plant or hydropower station.
The turbines rotate at the same rate as the grid–60 cycles per second (hertz) in the United States–and help provide stability for the grid, particularly during spikes in power demand or other disturbances. If the power plant goes offline for any reason, the inertia of the turbines maintains the grid’s frequency for a window of time while another power source is brought online to replace the offline generator.
Certain types of renewable energy, such as wind and solar photovoltaic, do not use rotational generators, instead using electronic inverters. But these renewable technologies include electronic sensors that can respond to changes in frequency quickly, and can replace the need for rotational inertia.Synthetic inertia – Inertia provided without synchronous generators and refers to the transfer of active power into the grid from a grid-forming inverter. This type of inertia can provide the same, or even better, stabilization services as traditional inertia because it has an instantaneous effect.
The process of connecting new power sources, like renewable energy generators or energy storage systems, to the existing grid infrastructure. It involves integrating these new sources with the grid’s transmission and distribution networks, ensuring a stable and reliable flow of electricity.
The line in which power generation and transmission projects must wait after they have requested to connect to the electric grid. These queues are managed by grid operators like ISOs (Independent System Operators) or RTOs (Regional Transmission Organizations). Projects are evaluated for their impact on the grid and the necessary upgrades before they can connect and deliver electricity.
A power source whose availability and output fluctuate due to natural variations in its energy source. This means the power supply isn’t consistently available, often linked to weather conditions like wind speed, time of day, or season. Renewable energy output can be forecast and stored in battery systems to maintain grid reliability.