TRENDING TERM

Critical Issue Fast Path (CIFP)

An accelerated stakeholder process used in PJM Interconnection to resolve urgent, contentious, and time-sensitive issues that cannot be resolved through the normal stakeholder process. The process involves several stages of discussion and proposal development, culminating in a submission to the Federal Energy Regulatory Commission (FERC) for approval. The CIFP process has been used in recent years to discuss large load additions (2025) and resource adequacy (2023).

TRENDING TERM

Effective Load Carrying Capability (ELCC)

Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions. 

TRENDING TERM

Disturbance

Refers to any unwanted or unplanned electrical event that interferes with the normal operation of the electrical grid. These can manifest in power outages, surges, and other events, and can originate from various sources within the electrical grid, such as loss of a large generating unit or another grid asset, such as a transmission line or transformer.

Can’t find the term you’re looking for? Submit it here!

202(c) Order

An emergency order issued by the United States Department of Energy (DOE) under Section 202(c) of the Federal Power Act. It allows the Secretary of Energy to temporarily order connections of facilities and the generation, delivery, or transmission of electricity to best meet an emergency caused by war, a sudden increase in demand, or a shortage of energy or facilities. These temporary orders can also exempt power plants from federal, state, or local environmental rules and have historically been used to prevent outages during severe weather events or supply shortfalls.

Active power

Also known as real or true power, is the portion of electrical power that does useful work in a circuit, such as generating heat, light, or mechanical energy. (see related: reactive power)

Advance Notice of Proposed Rulemaking (ANOPR)

A preliminary document used by government agencies to solicit public feedback on potential new rules or reforms before they are officially proposed. It outlines initial ideas, asks specific questions, and serves as the first step in a larger regulatory process. The acronym is frequently used by the Federal Energy Regulatory Commission (FERC). It precedes a formal Notice of Proposed Rulemaking (NOPR) and allows agencies to gauge public opinion and gather information to develop a more informed proposal.

Ancillary services

(see also: Essential reliability services) – Supplementary services essential for maintaining the reliable operation and stability of the electrical grid beyond the basic generation and transmission of energy. They are “behind-the-scenes” services that include real-time balancing of electricity supply and demand, maintaining voltage levels, and providing the capability to restart the grid after a widespread outage (black start). 

Automatic Generation Control (AGC)

Is an automated system that continuously monitors the electrical network and adjusts the power output of multiple generators. Its primary functions are to maintain system frequency (60 Hz in United States), in response to changes in the power demand, or load.

Hydrogen

Fuel cell that carries energy generated from another source. It can be used in fuel cells to generate electricity with water as the only byproduct, or it can be burned for heat. Hydrogen can be produced from a variety of sources–renewable energy such as solar or wind, or gas plants, nuclear, and other energy sources–which dictate whether it can be considered “clean” or not.

Independent Market Monitor (IMM)

An entity that is hired by an Independent System Operator (ISO) or Regional Transmission Organization (RTO) to oversee and assess the operations of the wholesale electricity market. Its primary role is to ensure fair and competitive market practices by monitoring market participant behavior and identifying potential market manipulation or design flaws.

Independent System Operator (ISO)

A non-profit organization that manages the electricity grid and wholesale electricity markets within a specific geographic region. Its primary role is to ensure the reliable and efficient delivery of electricity, balancing supply and demand in real-time and overseeing fair competition among market participants. 

  • List of ISOs and RTOs:
    • CAISO – California ISO
    • NYISO – New York ISO
    • Electric Reliability Council of Texas (ERCOT); also a Regional Reliability Council
    • MISO – Midcontinent Independent System Operator, serves northern Midwest, southeast, and parts of Canada
    • ISO-NE – ISO New England
    • SPP – Southwest Power Pool
    • PJM – Pennsylvania-New Jersey-Maryland Interconnection- services 13 states in Midatlantic and Midwest region
Inertia

In the context of the grid, it refers to the energy stored in the rotating machinery of generators, such as the turbines of a gas plant or hydropower station. 

The turbines rotate at the same rate as the grid–60 cycles per second (hertz) in the United States–and help provide stability for the grid, particularly during spikes in power demand or other disturbances. If the power plant goes offline for any reason, the inertia of the turbines maintains the grid’s frequency for a window of time while another power source is brought online to replace the offline generator. 

Certain types of renewable energy, such as wind and solar photovoltaic, do not use rotational generators, instead using electronic inverters. But these renewable technologies include electronic sensors that can respond to changes in frequency quickly, and can replace the need for rotational inertia.Synthetic inertia – Inertia provided without synchronous generators and refers to the transfer of active power into the grid from a grid-forming inverter. This type of inertia can provide the same, or even better, stabilization services as traditional inertia because it has an instantaneous effect.

Interconnection

The process of connecting new power sources, like renewable energy generators or energy storage systems, to the existing grid infrastructure. It involves integrating these new sources with the grid’s transmission and distribution networks, ensuring a stable and reliable flow of electricity.

Interconnection queue

The line in which power generation and transmission projects must wait after they have requested to connect to the electric grid. These queues are managed by grid operators like ISOs (Independent System Operators) or RTOs (Regional Transmission Organizations). Projects are evaluated for their impact on the grid and the necessary upgrades before they can connect and deliver electricity.

Intermittent power

A power source whose availability and output fluctuate due to natural variations in its energy source. This means the power supply isn’t consistently available, often linked to weather conditions like wind speed, time of day, or season. Renewable energy output can be forecast and stored in battery systems to maintain grid reliability.

Inverter

Technology that provides the interface between the grid and energy sources like solar panels, wind turbines, and energy storage, converting direct current to alternating current (which is how electricity is delivered in the United States). It is used to convert power output from solar cells, batteries, and wind turbines into power that can be injected into the grid.

Inverter-Based Resources (IBR)

A power generation or storage device (such as a battery) that connects to the electrical grid through an inverter, a power electronic device that converts direct current (DC) to alternating current (AC). These resources, including solar photovoltaic (PV) systems, wind turbines, and battery energy storage systems, are increasingly important for grid stability.

ISO-NE

ISO New England

Virtual Power Plant

A network of distributed energy resources—like rooftop solar panels, electric vehicle chargers, and smart water heaters—that work together to balance energy supply and demand on a large scale. They are usually run by local utility companies that oversee this balancing act.

Voltage

Often described as the “pressure” that pushes electric current through a circuit. It’s measured in volts (V) and is essentially the energy per unit charge. Think of it like water pressure: the higher the voltage, the greater the “push” on electrons, and the more current can flow.

Maintaining stable voltage on the grid  is critical to keeping the lights on and avoiding equipment damage. Voltage is not consistent across the grid, though it is locally constant, with higher voltages used for longer transmission lines and lower voltages used at the distribution level.

  • Voltage support – The ability of a power system to maintain stable voltage levels within a desired range, even during fluctuations or disturbances. It’s crucial for ensuring a reliable electricity supply and preventing equipment damage. Generally, it is achieved by a grid maintaining reactive power via generating units or other equipment absorbing or adding reactive power.