Grid Glossary

TRENDING TERM

Critical Issue Fast Path (CIFP)

An accelerated stakeholder process used in PJM Interconnection to resolve urgent, contentious, and time-sensitive issues that cannot be resolved through the normal stakeholder process. The process involves several stages of discussion and proposal development, culminating in a submission to the Federal Energy Regulatory Commission (FERC) for approval. The CIFP process has been used in recent years to discuss large load additions (2025) and resource adequacy (2023).

TRENDING TERM

Effective Load Carrying Capability (ELCC)

Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions. 

TRENDING TERM

Disturbance

Refers to any unwanted or unplanned electrical event that interferes with the normal operation of the electrical grid. These can manifest in power outages, surges, and other events, and can originate from various sources within the electrical grid, such as loss of a large generating unit or another grid asset, such as a transmission line or transformer.

Can’t find the term you’re looking for? Submit it here!

Economic dispatch

The mechanism for choosing the lowest cost energy option that meets energy needs, which gives cheaper renewable energy and battery storage an edge. 

  • Uneconomic dispatch – when a grid operator/utility chooses a higher-priced energy option, or above market-rate source, to meet electricity needs. This has emerged as a significant problem in areas where United States utilities are operating coal plants that can’t compete on cost with gas-fueled facilities and renewables. This practice allows utilities to continue to collect the costs of fuel and operations from customers to pay off their investment in the power plant.
Effective Load Carrying Capability (ELCC)

Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions. 

Energy efficiency

Measures that reduce electricity use in a home or business. These measures include replacing inefficient heating and air conditioners with heat pumps, adding attic insulation, and sealing ducts and foundation, walls, roof, windows, and doors of buildings. It also includes replacing energy-intensive appliances with more efficient ones. These measures can provide energy savings, improve comfort, and increase property values.

Energy-only interconnection approaches

Connecting new generation to the grid with minimal transmission upgrades and managing impacts through operational strategies rather than extensive upfront infrastructure investments. This approach, often referred to as “connect and manage,” prioritizes adding generation capacity quickly while relying on the grid operator to manage any resulting operational constraints. It requires new resources to risk curtailment (where the generator is asked to stop supplying power to the grid when supply is too high). The process has allowed Texas’ ERCOT to connect record numbers of new clean projects in the last several years significantly faster than other regions. 

ERCOT

The Electric Reliability Council of Texas serves as an independent system operator (ISO), managing the flow of electrical power over transmission infrastructure in the state of Texas.

Essential reliability services

A combination of automated and manual controls grid operators adjust to maintain grid reliability by ensuring a balance between supply (generation) and demand (load). They generally consist of three main aspects:

  • frequency response – short-term adjustments to maintain the grid’s oscillations at 60 hz)
  • balancing – related to frequency response but on longer time frames, to, for e.g., plan for energy resource outages due to maintenance, and 
  • voltage control – involves magnetic waves to allow for the movement of watts of energy
Hydrogen

Fuel cell that carries energy generated from another source. It can be used in fuel cells to generate electricity with water as the only byproduct, or it can be burned for heat. Hydrogen can be produced from a variety of sources–renewable energy such as solar or wind, or gas plants, nuclear, and other energy sources–which dictate whether it can be considered “clean” or not.

Large load

Historically refers to industrial facilities with high electrical demand. They had long interconnection timelines that allowed for more study time under traditional planning processes. Currently, emerging large loads include cryptocurrency mining, data centers (conventional and artificial intelligence), oil field loads, and hydrogen production facilities. Many have a shorter timeline to interconnect (months vs. years) to the grid. In addition to these rapid timelines, some emerging large loads introduce new challenges to grid operators like rapid demand fluctuations and increased voltage sensitivity.

Load

The amount of power or electricity consumed by a device or system at a given time. It’s the demand placed on an energy source, like a power grid or a battery, by the connected electrical equipment.

Load growth

The increase in the demand for electricity over time. It signifies the rising need for power from various sectors, including residential, commercial, and industrial, and can be driven by factors like population increases, economic development, and the adoption of new technologies like electric vehicles and data centers.

Load shed

A controlled process where a utility company reduces or shuts off power supply to certain areas or customers to balance demand with available supply, preventing a complete system failure. It’s a last-resort measure to maintain grid stability when demand exceeds supply or when there are issues with power generation or transmission.

Locational Marginal Price (LMP)

A way for wholesale electric energy prices to reflect the value of electric energy at different locations, accounting for the patterns of load, generation, and the physical limits of the transmission system.

Loss of Load Expectation (LOLE)

Analysis is typically performed on a system to determine the amount of capacity that needs to be installed to meet the desired reliability target, commonly expressed as an expected value, or LOLE of 0.1 days/year.

Siting requirements

For electricity infrastructure, like power lines and generating facilities, these requirements involve a range of considerations, including safety, environmental impact, and community engagement. Specific regulations vary by location and project type, but generally include distance requirements from existing infrastructure, environmental assessments, and engagement with landowners and stakeholders.

Solar power

The conversion of sunlight into electricity using photovoltaics (PV) or solar thermal technologies. It’s a renewable energy source that is becoming increasingly important in the global energy landscape due to its sustainability and decreasing costs.

Spot Price

Refers to the real-time wholesale cost of electricity that fluctuates based on supply, demand, weather, and grid conditions.

SPP

Southwest Power Pool

Synchronous resources

Generators with turbines rotating in sync with the grid frequency. They include large-scale thermal (coal and gas) and hydropower plants.

Watts

Measure of the rate of energy transfer over a unit of time, with one watt equal to one joule (J) per second.

Wind power

A form of renewable energy that uses the kinetic energy of wind to generate electricity. It involves capturing the wind’s energy through turbines, which then convert this mechanical energy into electricity. Modern wind power generation primarily relies on wind turbines, often grouped into wind farms, connected to the electrical grid.

Glossary Form

Your Name(Required)

Contact Us

We’re glad you are here!
For any inquiries or to contact one of our experts please fill out our form.
This field is for validation purposes and should be left unchanged.
© 2025 All rights reserved The Reliable Grid Project.