Grid Glossary

TRENDING TERM

Critical Issue Fast Path (CIFP)

An accelerated stakeholder process used in PJM Interconnection to resolve urgent, contentious, and time-sensitive issues that cannot be resolved through the normal stakeholder process. The process involves several stages of discussion and proposal development, culminating in a submission to the Federal Energy Regulatory Commission (FERC) for approval. The CIFP process has been used in recent years to discuss large load additions (2025) and resource adequacy (2023).

TRENDING TERM

Effective Load Carrying Capability (ELCC)

Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions. 

TRENDING TERM

Disturbance

Refers to any unwanted or unplanned electrical event that interferes with the normal operation of the electrical grid. These can manifest in power outages, surges, and other events, and can originate from various sources within the electrical grid, such as loss of a large generating unit or another grid asset, such as a transmission line or transformer.

Can’t find the term you’re looking for? Submit it here!

Economic dispatch

The mechanism for choosing the lowest cost energy option that meets energy needs, which gives cheaper renewable energy and battery storage an edge. 

  • Uneconomic dispatch – when a grid operator/utility chooses a higher-priced energy option, or above market-rate source, to meet electricity needs. This has emerged as a significant problem in areas where United States utilities are operating coal plants that can’t compete on cost with gas-fueled facilities and renewables. This practice allows utilities to continue to collect the costs of fuel and operations from customers to pay off their investment in the power plant.
Effective Load Carrying Capability (ELCC)

Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions. 

Energy efficiency

Measures that reduce electricity use in a home or business. These measures include replacing inefficient heating and air conditioners with heat pumps, adding attic insulation, and sealing ducts and foundation, walls, roof, windows, and doors of buildings. It also includes replacing energy-intensive appliances with more efficient ones. These measures can provide energy savings, improve comfort, and increase property values.

Energy-only interconnection approaches

Connecting new generation to the grid with minimal transmission upgrades and managing impacts through operational strategies rather than extensive upfront infrastructure investments. This approach, often referred to as “connect and manage,” prioritizes adding generation capacity quickly while relying on the grid operator to manage any resulting operational constraints. It requires new resources to risk curtailment (where the generator is asked to stop supplying power to the grid when supply is too high). The process has allowed Texas’ ERCOT to connect record numbers of new clean projects in the last several years significantly faster than other regions. 

ERCOT

The Electric Reliability Council of Texas serves as an independent system operator (ISO), managing the flow of electrical power over transmission infrastructure in the state of Texas.

Essential reliability services

A combination of automated and manual controls grid operators adjust to maintain grid reliability by ensuring a balance between supply (generation) and demand (load). They generally consist of three main aspects:

  • frequency response – short-term adjustments to maintain the grid’s oscillations at 60 hz)
  • balancing – related to frequency response but on longer time frames, to, for e.g., plan for energy resource outages due to maintenance, and 
  • voltage control – involves magnetic waves to allow for the movement of watts of energy
Federal Energy Regulatory Commission (FERC)

An independent agency that regulates the interstate transmission of natural gas, oil, and electricity. FERC also regulates natural gas and hydropower projects.

Federal Power Act

A United States law primarily regulating the interstate transmission and sale of electricity and the development of hydroelectric power. It was responsible for creating the body now known as FERC. It was created in 1920 and has been amended several times since. 

Firming requirements

Measures taken to ensure backup power, particularly of renewable energy, such as solar and wind generators. These requirements may require battery storage, ancillary services, or backup generation, such as an added gas plant to produce energy when a solar or wind plant does not.

Frequency

Electricity is supplied to homes and businesses in the United States in the form of alternating current, and frequency is the rate at which an alternating current changes direction, as measured in hertz (Hz). Across the power grid there is a consistent frequency which in the United States is 60 Hz. 

Frequency regulation or response

The ability of the grid to react to a change in

the frequency to bring it back to the normal operating frequency, which is 60 Hz in the United States

  • Inertial response refers to the injection of stored energy, such as battery energy, into the electricity grid to slow down a decline in frequency. 
  • Primary frequency response – The first line of defense against frequency fluctuations that could destabilize the grid. It takes the form of immediate, automatic adjustments in power output by generators and loads in response to frequency deviations in the electric grid.
  • Fast frequency response consists of the combined inertial response and primary frequency response. It injects energy in the seconds immediately following a disturbance to slow frequency decline and establishes the minimum frequency (called the nadir).
  • Secondary frequency response works on a slightly longer time frame than primary frequency response, on the order of 5-15 minutes. It maintains grid frequency and allows for scheduled energy transfers between balancing authorities, which include utilities, regional transmission operators, and other grid management entities.
Hydrogen

Fuel cell that carries energy generated from another source. It can be used in fuel cells to generate electricity with water as the only byproduct, or it can be burned for heat. Hydrogen can be produced from a variety of sources–renewable energy such as solar or wind, or gas plants, nuclear, and other energy sources–which dictate whether it can be considered “clean” or not.

MISO

Midcontinent Independent System Operator, serves northern Midwest, southeast, and parts of Canada

Queue

(see: Interconnection Queue)

Watts

Measure of the rate of energy transfer over a unit of time, with one watt equal to one joule (J) per second.

Wind power

A form of renewable energy that uses the kinetic energy of wind to generate electricity. It involves capturing the wind’s energy through turbines, which then convert this mechanical energy into electricity. Modern wind power generation primarily relies on wind turbines, often grouped into wind farms, connected to the electrical grid.

Winter peaking

The increase in energy demand during the winter months, usually due to heating needs. This can lead to higher energy prices and bills for a number of reasons, including: 

  • Strained energy grid: The high demand can strain the energy grid, which can cause utilities to work harder to meet the need.
  • Seasonal rate adjustments: Many energy providers adjust rates based on seasonal demand.
  • Increased use of lighting: Shorter and darker winter days can lead to greater use of in-home lighting.