Grid Glossary

TRENDING TERM

Critical Issue Fast Path (CIFP)

An accelerated stakeholder process used in PJM Interconnection to resolve urgent, contentious, and time-sensitive issues that cannot be resolved through the normal stakeholder process. The process involves several stages of discussion and proposal development, culminating in a submission to the Federal Energy Regulatory Commission (FERC) for approval. The CIFP process has been used in recent years to discuss large load additions (2025) and resource adequacy (2023).

TRENDING TERM

Effective Load Carrying Capability (ELCC)

Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions. 

TRENDING TERM

Disturbance

Refers to any unwanted or unplanned electrical event that interferes with the normal operation of the electrical grid. These can manifest in power outages, surges, and other events, and can originate from various sources within the electrical grid, such as loss of a large generating unit or another grid asset, such as a transmission line or transformer.

Can’t find the term you’re looking for? Submit it here!

Demand-response programs

These incentivize customers to reduce, increase, or shift their electricity consumption in response to price spikes or grid reliability signals. Most programs encourage utility customers primarily through price incentives to shift electricity consumption from hours of high demand (relative to energy supply) to hours when energy supply is plentiful (relative to demand).

Demand-side solutions

These encompass strategies and programs designed to influence electricity consumption patterns on the customer side of the meter. These initiatives aim to moderate electricity demand through methods such as financial incentives for energy conservation and energy efficiency measures, like improved insulation or the adoption of energy-efficient appliances. 

Dispatchable energy

Refers to electricity generation resources that power grid operators can control and adjust on demand to meet changing electricity needs. These include nuclear, hydropower, battery storage, and thermal power plants.

Distributed Energy Sources (DER)

Small-scale energy generation and storage technologies located near the point where the energy is used, rather than at a centralized power plant. These resources–such as solar microgrids, rooftop solar, and battery storage–can be used to enhance or replace traditional energy sources and can operate independently or be connected to the main grid. 

Disturbance

Refers to any unwanted or unplanned electrical event that interferes with the normal operation of the electrical grid. These can manifest in power outages, surges, and other events, and can originate from various sources within the electrical grid, such as loss of a large generating unit or another grid asset, such as a transmission line or transformer.

Disturbance ride-through

The ability of a piece of electrical equipment to stay connected to the grid through a short-term disturbance, thus helping keep the grid stable through the event. Inverter-based resources, such as photovoltaic solar arrays, wind turbines, and battery storage, can provide disturbance ride-through services, but require specific design of their control system to do so.

Docket

In energy regulation, it is a formal proceeding or official record initiated by a regulatory body (such as a Public Utilities Commission or the Federal Energy Regulatory Commission (FERC)) to address a specific issue or project. It serves as a repository for all submitted documents, evidence, and public comments.

Duck curve

A visual representation of how solar power generation impacts the daily electricity demand curve, particularly in regions with high solar adoption like California. It depicts a dip in net electricity demand during midday due to solar generation, followed by a steep increase in the evening as solar output decreases and demand peaks.

Federal Energy Regulatory Commission (FERC)

An independent agency that regulates the interstate transmission of natural gas, oil, and electricity. FERC also regulates natural gas and hydropower projects.

Federal Power Act

A United States law primarily regulating the interstate transmission and sale of electricity and the development of hydroelectric power. It was responsible for creating the body now known as FERC. It was created in 1920 and has been amended several times since. 

Firming requirements

Measures taken to ensure backup power, particularly of renewable energy, such as solar and wind generators. These requirements may require battery storage, ancillary services, or backup generation, such as an added gas plant to produce energy when a solar or wind plant does not.

Frequency

Electricity is supplied to homes and businesses in the United States in the form of alternating current, and frequency is the rate at which an alternating current changes direction, as measured in hertz (Hz). Across the power grid there is a consistent frequency which in the United States is 60 Hz. 

Frequency regulation or response

The ability of the grid to react to a change in

the frequency to bring it back to the normal operating frequency, which is 60 Hz in the United States

  • Inertial response refers to the injection of stored energy, such as battery energy, into the electricity grid to slow down a decline in frequency. 
  • Primary frequency response – The first line of defense against frequency fluctuations that could destabilize the grid. It takes the form of immediate, automatic adjustments in power output by generators and loads in response to frequency deviations in the electric grid.
  • Fast frequency response consists of the combined inertial response and primary frequency response. It injects energy in the seconds immediately following a disturbance to slow frequency decline and establishes the minimum frequency (called the nadir).
  • Secondary frequency response works on a slightly longer time frame than primary frequency response, on the order of 5-15 minutes. It maintains grid frequency and allows for scheduled energy transfers between balancing authorities, which include utilities, regional transmission operators, and other grid management entities.
Hydrogen

Fuel cell that carries energy generated from another source. It can be used in fuel cells to generate electricity with water as the only byproduct, or it can be burned for heat. Hydrogen can be produced from a variety of sources–renewable energy such as solar or wind, or gas plants, nuclear, and other energy sources–which dictate whether it can be considered “clean” or not.

MISO

Midcontinent Independent System Operator, serves northern Midwest, southeast, and parts of Canada

Offshore wind

Wind turbines erected in bodies of water that harness the power of wind, converting it into electricity that is then transmitted to the mainland to power homes and businesses. Offshore wind farms are considered a renewable energy source.

Operational reliability

The real-time balancing of energy supply and demand to maintain frequency and voltage within safe operating limits. It is the shorter-term dimension of reliability and requires regular monitoring and control of the entire grid. It includes the ability to quickly respond to sudden changes, like the loss of a major power plant or transmission line, and to handle normal variations in supply and demand.

Reactive power

Power that does not perform useful work but is used to establish and maintain electromagnetic fields that are needed to generate, transmit, and convert electric power in the alternating current network. A shortage of reactive power can cause voltage to decline. (See also: voltage support)

Reliability

A characteristic of the whole electricity system to describe its ability to consistently deliver electricity to consumers without interruption, even through grid disturbances. Reliability comes down to having sufficient generating resources to meet demand and a functional operational grid system.

Reliability must-run (RMR) contract

An agreement initiated by an RTO or ISO with a power plant, keeping it in operation temporarily for reliability purposes.