Also known as real or true power, is the portion of electrical power that does useful work in a circuit, such as generating heat, light, or mechanical energy. (see related: reactive power)
A preliminary document used by government agencies to solicit public feedback on potential new rules or reforms before they are officially proposed. It outlines initial ideas, asks specific questions, and serves as the first step in a larger regulatory process. The acronym is frequently used by the Federal Energy Regulatory Commission (FERC). It precedes a formal Notice of Proposed Rulemaking (NOPR) and allows agencies to gauge public opinion and gather information to develop a more informed proposal.
(see also: Essential reliability services) – Supplementary services essential for maintaining the reliable operation and stability of the electrical grid beyond the basic generation and transmission of energy. They are “behind-the-scenes” services that include real-time balancing of electricity supply and demand, maintaining voltage levels, and providing the capability to restart the grid after a widespread outage (black start).
Is an automated system that continuously monitors the electrical network and adjusts the power output of multiple generators. Its primary functions are to maintain system frequency (60 Hz in United States), in response to changes in the power demand, or load.
California ISO
The maximum amount of power an energy source can physically produce (measured in megawatts/MW), or when referring to an electrical grid, the total amount of electricity that power plants connected to the grid are capable of producing. It’s essentially the total potential output of all the electricity sources, like coal, nuclear, hydro, wind, and solar plants. Meanwhile, energy is the actual output of a source over a particular time period.
Generally, participants submit sealed bids to offer capacity at specific prices. The auction ends when the total capacity offered matches the region’s needs, and a single clearing price is set for all commitments.
An energy source that generates electricity with zero- or extremely low-carbon emissions, and can do so when needed, regardless of weather conditions. They include enhanced geothermal energy and advanced nuclear technologies. They also can include solar or wind paired with battery storage to provide on-demand power supply regardless of weather conditions or time of day.
Refers to a regulatory approach for connecting new power generators to the electrical grid, notably used in Texas (ERCOT). This approach allows new generators to connect expeditiously with minimal upfront transmission upgrades. However, the grid operator retains the right to curtail their output if transmission constraints arise. This contrasts with approaches where developers pay for upgrades prior to connection. (see Energy-only interconnection approaches)
An accelerated stakeholder process used in PJM Interconnection to resolve urgent, contentious, and time-sensitive issues that cannot be resolved through the normal stakeholder process. The process involves several stages of discussion and proposal development, culminating in a submission to the Federal Energy Regulatory Commission (FERC) for approval. The CIFP process has been used in recent years to discuss large load additions (2025) and resource adequacy (2023).
The mechanism for choosing the lowest cost energy option that meets energy needs, which gives cheaper renewable energy and battery storage an edge.
Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions.
Measures that reduce electricity use in a home or business. These measures include replacing inefficient heating and air conditioners with heat pumps, adding attic insulation, and sealing ducts and foundation, walls, roof, windows, and doors of buildings. It also includes replacing energy-intensive appliances with more efficient ones. These measures can provide energy savings, improve comfort, and increase property values.
Connecting new generation to the grid with minimal transmission upgrades and managing impacts through operational strategies rather than extensive upfront infrastructure investments. This approach, often referred to as “connect and manage,” prioritizes adding generation capacity quickly while relying on the grid operator to manage any resulting operational constraints. It requires new resources to risk curtailment (where the generator is asked to stop supplying power to the grid when supply is too high). The process has allowed Texas’ ERCOT to connect record numbers of new clean projects in the last several years significantly faster than other regions.
The Electric Reliability Council of Texas serves as an independent system operator (ISO), managing the flow of electrical power over transmission infrastructure in the state of Texas.
A combination of automated and manual controls grid operators adjust to maintain grid reliability by ensuring a balance between supply (generation) and demand (load). They generally consist of three main aspects:
A non-profit organization that represents state public service commissions, which regulate essential utility services like energy, telecommunications, and water. Its stated aim is to improve the quality and effectiveness of public utility regulation. It has eight committees:
It also has a task force focused on Innovation.
Non-profit organization that operates to assure the effective and efficient reduction of risks to the reliability and security of the grid. It oversees six regional reliability entities and encompasses all of the interconnected power systems of Canada and the contiguous United States, as well as a portion of the Mexican state of Baja California. Its responsibilities include working with all stakeholders to develop standards for power system operation, monitoring and enforcing compliance with those standards, assessing resource adequacy, and providing educational and training resources as part of an accreditation program. NERC also investigates and analyzes the causes of significant power system disturbances in order to help prevent future events and produces reports about the near and long-term reliability forecast.
A document used by government agencies to announce a potential new rule or amendment to an existing one. This is an official part of the law-making process, allowing public comment before the rule is finalized. The acronym is frequently used by the Federal Energy Regulatory Commission (FERC).
A government-owned, contractor-operated facility, funded and overseen by the United States Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE). It specializes in the research and development of renewable energy, energy efficiency, energy systems integration, and sustainable transportation.
New York ISO