An emergency order issued by the United States Department of Energy (DOE) under Section 202(c) of the Federal Power Act. It allows the Secretary of Energy to temporarily order connections of facilities and the generation, delivery, or transmission of electricity to best meet an emergency caused by war, a sudden increase in demand, or a shortage of energy or facilities. These temporary orders can also exempt power plants from federal, state, or local environmental rules and have historically been used to prevent outages during severe weather events or supply shortfalls.
An independent agency that regulates the interstate transmission of natural gas, oil, and electricity. FERC also regulates natural gas and hydropower projects.
A United States law primarily regulating the interstate transmission and sale of electricity and the development of hydroelectric power. It was responsible for creating the body now known as FERC. It was created in 1920 and has been amended several times since.
Measures taken to ensure backup power, particularly of renewable energy, such as solar and wind generators. These requirements may require battery storage, ancillary services, or backup generation, such as an added gas plant to produce energy when a solar or wind plant does not.
Electricity is supplied to homes and businesses in the United States in the form of alternating current, and frequency is the rate at which an alternating current changes direction, as measured in hertz (Hz). Across the power grid there is a consistent frequency which in the United States is 60 Hz.
The ability of the grid to react to a change in
the frequency to bring it back to the normal operating frequency, which is 60 Hz in the United States
Historically refers to industrial facilities with high electrical demand. They had long interconnection timelines that allowed for more study time under traditional planning processes. Currently, emerging large loads include cryptocurrency mining, data centers (conventional and artificial intelligence), oil field loads, and hydrogen production facilities. Many have a shorter timeline to interconnect (months vs. years) to the grid. In addition to these rapid timelines, some emerging large loads introduce new challenges to grid operators like rapid demand fluctuations and increased voltage sensitivity.
The amount of power or electricity consumed by a device or system at a given time. It’s the demand placed on an energy source, like a power grid or a battery, by the connected electrical equipment.
The increase in the demand for electricity over time. It signifies the rising need for power from various sectors, including residential, commercial, and industrial, and can be driven by factors like population increases, economic development, and the adoption of new technologies like electric vehicles and data centers.
A controlled process where a utility company reduces or shuts off power supply to certain areas or customers to balance demand with available supply, preventing a complete system failure. It’s a last-resort measure to maintain grid stability when demand exceeds supply or when there are issues with power generation or transmission.
A way for wholesale electric energy prices to reflect the value of electric energy at different locations, accounting for the patterns of load, generation, and the physical limits of the transmission system.
Analysis is typically performed on a system to determine the amount of capacity that needs to be installed to meet the desired reliability target, commonly expressed as an expected value, or LOLE of 0.1 days/year.
Wind turbines erected in bodies of water that harness the power of wind, converting it into electricity that is then transmitted to the mainland to power homes and businesses. Offshore wind farms are considered a renewable energy source.
The real-time balancing of energy supply and demand to maintain frequency and voltage within safe operating limits. It is the shorter-term dimension of reliability and requires regular monitoring and control of the entire grid. It includes the ability to quickly respond to sudden changes, like the loss of a major power plant or transmission line, and to handle normal variations in supply and demand.
Power that does not perform useful work but is used to establish and maintain electromagnetic fields that are needed to generate, transmit, and convert electric power in the alternating current network. A shortage of reactive power can cause voltage to decline. (See also: voltage support)
A characteristic of the whole electricity system to describe its ability to consistently deliver electricity to consumers without interruption, even through grid disturbances. Reliability comes down to having sufficient generating resources to meet demand and a functional operational grid system.
An agreement initiated by an RTO or ISO with a power plant, keeping it in operation temporarily for reliability purposes.
The ability of the grid to ride through extreme events, recover quickly, and support other critical systems (e.g., transportation, health care, public safety etc.).
An assessment of whether the current or projected resource mix is sufficient to meet capacity and energy needs for a particular grid. The resource mix includes all resources able to provide capacity and energy to the system. Adequacy assessments are used to identify potential shortfalls in the availability of resources across different time frames; from long-term planning (5 to 20+ years) to seasonal and day-ahead assessments.
(see also: ISO) – A non-profit organization that manages the electricity transmission system in a specific region, ensuring reliable and efficient electricity delivery. RTOs operate the high-voltage electricity grid, facilitating the movement of power from generating plants to substations and ultimately to consumers. They also oversee competitive wholesale electricity markets.