Grid Glossary

TRENDING TERM

Critical Issue Fast Path (CIFP)

An accelerated stakeholder process used in PJM Interconnection to resolve urgent, contentious, and time-sensitive issues that cannot be resolved through the normal stakeholder process. The process involves several stages of discussion and proposal development, culminating in a submission to the Federal Energy Regulatory Commission (FERC) for approval. The CIFP process has been used in recent years to discuss large load additions (2025) and resource adequacy (2023).

TRENDING TERM

Effective Load Carrying Capability (ELCC)

Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions. 

TRENDING TERM

Disturbance

Refers to any unwanted or unplanned electrical event that interferes with the normal operation of the electrical grid. These can manifest in power outages, surges, and other events, and can originate from various sources within the electrical grid, such as loss of a large generating unit or another grid asset, such as a transmission line or transformer.

Can’t find the term you’re looking for? Submit it here!

202(c) Order

An emergency order issued by the United States Department of Energy (DOE) under Section 202(c) of the Federal Power Act. It allows the Secretary of Energy to temporarily order connections of facilities and the generation, delivery, or transmission of electricity to best meet an emergency caused by war, a sudden increase in demand, or a shortage of energy or facilities. These temporary orders can also exempt power plants from federal, state, or local environmental rules and have historically been used to prevent outages during severe weather events or supply shortfalls.

CAISO

California ISO

Capacity

The maximum amount of power an energy source can physically produce (measured in megawatts/MW), or when referring to an electrical grid, the total amount of electricity that power plants connected to the grid are capable of producing. It’s essentially the total potential output of all the electricity sources, like coal, nuclear, hydro, wind, and solar plants. Meanwhile, energy is the actual output of a source over a particular time period. 

  • Capacity accreditation – The process by which grid operators determine the reliability contribution of individual power resources (such as power plants or energy storage systems) to the overall electricity grid. It quantifies how much a resource can reliably contribute to meeting demand, especially during peak times or periods of tight supply, guiding investment decisions for grid stability.
  • Capacity auction – A competitive market mechanism where grid operators or utilities purchase energy in the market from electricity generators (such as coal plants, wind, and solar farms) or demand-response participants for future energy needs. Essentially, the generators or demand-response entities provide their energy or technology for future periods of high demand. Capacity market auctions ensure enough electricity is available for future demand at the lowest achievable price for consumers. The goal is to balance reliability with cost by having market participants compete. There are two main types of auctions:
    • Forward capacity auctions: held years before the capacity is needed, giving operators time to upgrade or build facilities. 
    • Incremental auctions: take place closer to the delivery time, adjusting for changes in demand or unexpected generator issues.  

Generally, participants submit sealed bids to offer capacity at specific prices. The auction ends when the total capacity offered matches the region’s needs, and a single clearing price is set for all commitments.  

  • Capacity costs – The charges associated with ensuring a sufficient supply of power to meet peak demand. These charges cover the cost of maintaining and operating power plants, transmission infrastructure, and other components needed to meet the highest levels of electricity usage, essentially guaranteeing power is available when it’s most needed.
  • Capacity market – A type of wholesale market designed to ensure there will be enough power generation available in the future to meet peak demand and maintain grid reliability. Generators receive payments for promising to be available to produce electricity when needed, even if they aren’t running all the time. Functions sort of like an insurance policy, in that generators are paid for the promise to show up with power during times of high demand. This type of market is a method to maintain resource adequacy. Not all markets use this method (example: Electric Reliability Council of Texas (ERCOT).
Clean firm energy

An energy source that generates electricity with zero- or extremely low-carbon emissions, and can do so when needed, regardless of weather conditions. They include enhanced geothermal energy and advanced nuclear technologies. They also can include solar or wind paired with battery storage to provide on-demand power supply regardless of weather conditions or time of day. 

Connect and manage

Refers to a regulatory approach for connecting new power generators to the electrical grid, notably used in Texas (ERCOT). This approach allows new generators to connect expeditiously with minimal upfront transmission upgrades. However, the grid operator retains the right to curtail their output if transmission constraints arise. This contrasts with approaches where developers pay for upgrades prior to connection. (see Energy-only interconnection approaches)

Critical Issue Fast Path (CIFP)

An accelerated stakeholder process used in PJM Interconnection to resolve urgent, contentious, and time-sensitive issues that cannot be resolved through the normal stakeholder process. The process involves several stages of discussion and proposal development, culminating in a submission to the Federal Energy Regulatory Commission (FERC) for approval. The CIFP process has been used in recent years to discuss large load additions (2025) and resource adequacy (2023).

Federal Energy Regulatory Commission (FERC)

An independent agency that regulates the interstate transmission of natural gas, oil, and electricity. FERC also regulates natural gas and hydropower projects.

Federal Power Act

A United States law primarily regulating the interstate transmission and sale of electricity and the development of hydroelectric power. It was responsible for creating the body now known as FERC. It was created in 1920 and has been amended several times since. 

Firming requirements

Measures taken to ensure backup power, particularly of renewable energy, such as solar and wind generators. These requirements may require battery storage, ancillary services, or backup generation, such as an added gas plant to produce energy when a solar or wind plant does not.

Frequency

Electricity is supplied to homes and businesses in the United States in the form of alternating current, and frequency is the rate at which an alternating current changes direction, as measured in hertz (Hz). Across the power grid there is a consistent frequency which in the United States is 60 Hz. 

Frequency regulation or response

The ability of the grid to react to a change in

the frequency to bring it back to the normal operating frequency, which is 60 Hz in the United States

  • Inertial response refers to the injection of stored energy, such as battery energy, into the electricity grid to slow down a decline in frequency. 
  • Primary frequency response – The first line of defense against frequency fluctuations that could destabilize the grid. It takes the form of immediate, automatic adjustments in power output by generators and loads in response to frequency deviations in the electric grid.
  • Fast frequency response consists of the combined inertial response and primary frequency response. It injects energy in the seconds immediately following a disturbance to slow frequency decline and establishes the minimum frequency (called the nadir).
  • Secondary frequency response works on a slightly longer time frame than primary frequency response, on the order of 5-15 minutes. It maintains grid frequency and allows for scheduled energy transfers between balancing authorities, which include utilities, regional transmission operators, and other grid management entities.
Siting requirements

For electricity infrastructure, like power lines and generating facilities, these requirements involve a range of considerations, including safety, environmental impact, and community engagement. Specific regulations vary by location and project type, but generally include distance requirements from existing infrastructure, environmental assessments, and engagement with landowners and stakeholders.

Solar power

The conversion of sunlight into electricity using photovoltaics (PV) or solar thermal technologies. It’s a renewable energy source that is becoming increasingly important in the global energy landscape due to its sustainability and decreasing costs.

Spot Price

Refers to the real-time wholesale cost of electricity that fluctuates based on supply, demand, weather, and grid conditions.

SPP

Southwest Power Pool

Synchronous resources

Generators with turbines rotating in sync with the grid frequency. They include large-scale thermal (coal and gas) and hydropower plants.

Virtual Power Plant

A network of distributed energy resources—like rooftop solar panels, electric vehicle chargers, and smart water heaters—that work together to balance energy supply and demand on a large scale. They are usually run by local utility companies that oversee this balancing act.

Voltage

Often described as the “pressure” that pushes electric current through a circuit. It’s measured in volts (V) and is essentially the energy per unit charge. Think of it like water pressure: the higher the voltage, the greater the “push” on electrons, and the more current can flow.

Maintaining stable voltage on the grid  is critical to keeping the lights on and avoiding equipment damage. Voltage is not consistent across the grid, though it is locally constant, with higher voltages used for longer transmission lines and lower voltages used at the distribution level.

  • Voltage support – The ability of a power system to maintain stable voltage levels within a desired range, even during fluctuations or disturbances. It’s crucial for ensuring a reliable electricity supply and preventing equipment damage. Generally, it is achieved by a grid maintaining reactive power via generating units or other equipment absorbing or adding reactive power.

Glossary Form

Your Name(Required)

Contact Us

We’re glad you are here!
For any inquiries or to contact one of our experts please fill out our form.
This field is for validation purposes and should be left unchanged.
© 2025 All rights reserved The Reliable Grid Project.