Grid Glossary

TRENDING TERM

Critical Issue Fast Path (CIFP)

An accelerated stakeholder process used in PJM Interconnection to resolve urgent, contentious, and time-sensitive issues that cannot be resolved through the normal stakeholder process. The process involves several stages of discussion and proposal development, culminating in a submission to the Federal Energy Regulatory Commission (FERC) for approval. The CIFP process has been used in recent years to discuss large load additions (2025) and resource adequacy (2023).

TRENDING TERM

Effective Load Carrying Capability (ELCC)

Measurement used to calculate how much an energy resource–such as a wind farm or solar array–contributes to the overall reliability of the grid. It assesses the resource’s ability to meet electricity demand, particularly during peak usage periods, and is especially useful for variable renewable energy sources whose output depends on factors like weather conditions. 

TRENDING TERM

Disturbance

Refers to any unwanted or unplanned electrical event that interferes with the normal operation of the electrical grid. These can manifest in power outages, surges, and other events, and can originate from various sources within the electrical grid, such as loss of a large generating unit or another grid asset, such as a transmission line or transformer.

Can’t find the term you’re looking for? Submit it here!

202(c) Order

An emergency order issued by the United States Department of Energy (DOE) under Section 202(c) of the Federal Power Act. It allows the Secretary of Energy to temporarily order connections of facilities and the generation, delivery, or transmission of electricity to best meet an emergency caused by war, a sudden increase in demand, or a shortage of energy or facilities. These temporary orders can also exempt power plants from federal, state, or local environmental rules and have historically been used to prevent outages during severe weather events or supply shortfalls.

Active power

Also known as real or true power, is the portion of electrical power that does useful work in a circuit, such as generating heat, light, or mechanical energy. (see related: reactive power)

Advance Notice of Proposed Rulemaking (ANOPR)

A preliminary document used by government agencies to solicit public feedback on potential new rules or reforms before they are officially proposed. It outlines initial ideas, asks specific questions, and serves as the first step in a larger regulatory process. The acronym is frequently used by the Federal Energy Regulatory Commission (FERC). It precedes a formal Notice of Proposed Rulemaking (NOPR) and allows agencies to gauge public opinion and gather information to develop a more informed proposal.

Ancillary services

(see also: Essential reliability services) – Supplementary services essential for maintaining the reliable operation and stability of the electrical grid beyond the basic generation and transmission of energy. They are “behind-the-scenes” services that include real-time balancing of electricity supply and demand, maintaining voltage levels, and providing the capability to restart the grid after a widespread outage (black start). 

Automatic Generation Control (AGC)

Is an automated system that continuously monitors the electrical network and adjusts the power output of multiple generators. Its primary functions are to maintain system frequency (60 Hz in United States), in response to changes in the power demand, or load.

Generation

The process of creating electricity. 

Geothermal energy

Heat derived from the Earth’s interior, which can be harnessed for electricity generation. It’s a renewable resource, as the Earth’s internal heat is continuously replenished.

Grid

The electrical grid is a vast, interconnected network comprising power plants, transmission lines, substations, and distribution lines. Its purpose is to generate, transmit, and deliver electricity from producers to consumers across a wide geographic area. 

Grid enhancing technologies (GETs)

A variety of technologies that improve the capacity, efficiency, and reliability of existing power grids. They are often lower cost and faster to deploy than major grid infrastructure upgrades like building new transmission lines. These technologies optimize the flow of electricity across existing infrastructure.

Grid following inverter

Refers to the ability of an inverter to synchronize with frequency and voltage on the grid. These are more common than grid forming and refer to how this technology takes its cues from the grid, not the other way around.

Grid forming inverter

Refers to the ability of an inverter to actively control frequency and voltage on the grid, helping to ensure grid stability. They can provide ancillary services, such as inertia, voltage regulation, and frequency response, essential for maintaining grid stability.

Grid hardening

Refers to the many solutions that help the grid withstand major events, such as extreme weather, natural disasters, or cyber attacks, without disruption.

Siting requirements

For electricity infrastructure, like power lines and generating facilities, these requirements involve a range of considerations, including safety, environmental impact, and community engagement. Specific regulations vary by location and project type, but generally include distance requirements from existing infrastructure, environmental assessments, and engagement with landowners and stakeholders.

Solar power

The conversion of sunlight into electricity using photovoltaics (PV) or solar thermal technologies. It’s a renewable energy source that is becoming increasingly important in the global energy landscape due to its sustainability and decreasing costs.

Spot Price

Refers to the real-time wholesale cost of electricity that fluctuates based on supply, demand, weather, and grid conditions.

SPP

Southwest Power Pool

Synchronous resources

Generators with turbines rotating in sync with the grid frequency. They include large-scale thermal (coal and gas) and hydropower plants.

Virtual Power Plant

A network of distributed energy resources—like rooftop solar panels, electric vehicle chargers, and smart water heaters—that work together to balance energy supply and demand on a large scale. They are usually run by local utility companies that oversee this balancing act.

Voltage

Often described as the “pressure” that pushes electric current through a circuit. It’s measured in volts (V) and is essentially the energy per unit charge. Think of it like water pressure: the higher the voltage, the greater the “push” on electrons, and the more current can flow.

Maintaining stable voltage on the grid  is critical to keeping the lights on and avoiding equipment damage. Voltage is not consistent across the grid, though it is locally constant, with higher voltages used for longer transmission lines and lower voltages used at the distribution level.

  • Voltage support – The ability of a power system to maintain stable voltage levels within a desired range, even during fluctuations or disturbances. It’s crucial for ensuring a reliable electricity supply and preventing equipment damage. Generally, it is achieved by a grid maintaining reactive power via generating units or other equipment absorbing or adding reactive power.
Watts

Measure of the rate of energy transfer over a unit of time, with one watt equal to one joule (J) per second.

Glossary Form

Your Name(Required)

Contact Us

We’re glad you are here!
For any inquiries or to contact one of our experts please fill out our form.
This field is for validation purposes and should be left unchanged.
© 2025 All rights reserved The Reliable Grid Project.